CUSTODY LEDGER LIVE ·
Field Operations · Controlled Procedure

VC-SOP-0610 — Specimen Transfer & Chain-of-Custody

The procedure governing every specimen movement — between zones, to the laboratory, into containment, or off-site — such that an unbroken, signed custody record exists for each specimen at all times.

SOP ID: VC-SOP-0610 Rev: B Effective: 2091-04-22 Next Review: 2093-04-22 Owner: Custody & Records Officer (OPS-FLD) Approver: Dr. P. L. Isley, CBO Class: Field Operations · Records Integrity
No specimen moves without a custody transfer. Every handoff requires a releasing and a receiving signature against a verified specimen ID. A gap in the custody chain invalidates the specimen's provenance and triggers a records investigation. For GCL-3+ specimens, transfer is co-governed by Containment.

1. Purpose

To define the controlled method for transferring custody of any specimen so that its location, handler, and condition are continuously documented; that no specimen is misplaced, substituted, or moved without authorization; and that provenance is defensible for research, regulatory, and security purposes.

2. Scope

Applies to all specimen movements within GreenWorld Sector-7 and to any off-site transfer. Intake into the facility is governed by VC-SOP-0205; GCL-4 movements additionally invoke VC-SOP-0204; off-site recovery follows VC-SOP-0501. This SOP is the authoritative custody record procedure for all of the above.

3. Definitions

TermDefinition
CustodyDocumented physical control of a specimen by a single accountable person at a given time.
TransferA handoff of custody from a releasing to a receiving custodian, with matched signatures.
Custody LedgerThe MDF-backed, append-only record of every transfer for a specimen.
Specimen TagThe tamper-evident identifier (RFID + printed ID) bound to a specimen at intake.
Custody GapAny period or move without a matched releasing/receiving signature.
Seal VerificationConfirmation that the tamper seal and tag match the ledger at handoff.

4. Responsibilities

RoleResponsibility
Custody & Records Officer (Owner)Owns the custody ledger and this SOP; investigates any custody gap.
Releasing CustodianVerifies ID and seal, signs release, hands off the specimen.
Receiving CustodianVerifies ID and seal on receipt, signs acceptance, assumes custody.
Containment OfficerCo-authorizes any GCL-3+ transfer.
CHLORAMaintains the append-only ledger; reads RFID at gates; alarms on unauthorized movement.

5. Equipment & Pre-Checks

6. Transfer Authorization Matrix

Transfer TypeAuthorizerContainerCo-Sign
Intra-zone (same wing)Zone LeadStandard tray
Inter-zone / to labCustody & Records OfficerSealed container
Into containment (GCL-3+)Containment OfficerSealed, grade-ratedContainment
GCL-4 movementContainment OfficerBio-Vault transportContainment + Directorate
Off-site transferCustody & Records OfficerTamper-locked, trackedDirector of Ops

7. Procedure

7.1 Authorization

  1. The requester opens a transfer in the custody ledger, stating specimen ID, origin, destination, and reason.
  2. The appropriate authorizer (Section 6) approves; GCL-3+ requires Containment co-sign before the specimen is touched.
  3. CHLORA validates that the specimen is cleared to move (not under quarantine hold per VC-SOP-0205, not locked for sampling).

7.2 Release

  1. Releasing Custodian scans the specimen tag and confirms the printed ID matches the ledger.
  2. Verify the tamper seal is intact and the container is grade-appropriate; note specimen condition.
  3. Sign the release in the ledger. Custody is not transferred until the receiving signature is captured.

7.3 In-Transit Control

  1. The specimen stays under one named custodian for the entire move; no unattended drops.
  2. RFID gates log passage automatically; an off-route or unauthorized read raises an unauthorized-movement alarm.
  3. For off-site transfers, GPS-tracked container and scheduled custody check-ins are required.

7.4 Receipt

  1. Receiving Custodian scans the tag, confirms ID match and seal integrity, and inspects condition against the release note.
  2. Any discrepancy — ID mismatch, broken seal, condition change — halts the transfer and opens a custody investigation.
  3. On a clean match, the receiver signs acceptance; CHLORA closes the transfer and updates the specimen's current location.

7.5 Quality Checkpoints

8. Exception Handling

ExceptionIndicationImmediate Action
ID MismatchTag does not match ledgerHalt transfer; quarantine the item; Custody Officer reconciles before any further move.
Broken SealTamper seal compromisedTreat as potential breach; isolate; screen per VC-SOP-0205; open investigation.
Custody GapMove with no matched signatureSpecimen provenance suspended; Custody Officer investigation; notify Director of Ops.
Unauthorized MovementRFID gate read off-routeCHLORA alarms; lock destination gates; locate specimen and custodian per monitoring.

9. Records

10. References

11. Revision History

RevDateAuthorSummary
A2089-03-19Custody & Records OfficerInitial issue; matched-signature transfer model and ledger established.
B2091-04-22Custody & Records OfficerRFID gate logging, off-site GPS tracking, and append-only corrective-entry rule added. CBO approval.